Machinery International Corp
20 Commerce Dr
,
North Branford CT 06471-1250
Tel:
203-484-0400
Fax:
203-484-4499
Email:
sales@machyintl.com
Web:
www.machyintl.com
0F5304 FURNACES, BELT CONVEYOR
30" W. x 7" H. x 240" L., KEITH, 1996, ELECTRIC BELT (10022)
Our reference:
10022
Click on picture below for larger version
MACHINE # 10022
SPECIFICATIONS:
MAXIMUM TEMPERATURE: 1300 DEG. F.
WORKING DIMENSIONS:
BELT WIDTH: 30"
WORKING HEIGHT: 7"
LOADING TABLE: 5 FT.
PREHEATING SECTION:
- (ZONE 1): 7 FT.
MAIN HEATING SECTIONS:
- (ZONES 2-6): 20 FT.
FREE COOLING: 8 FT.
UNLOADING TABLE: 5 FT.
OVERALL LENGTH: 45 FT.
HEATING SYSTEM:
ELECTRIC PLUG ASSEMBLIES IN PREHEATING SECTIONS
WIRE COILS ON CERAMIC RODS IN MAIN HEATING SECTIONS:
ZONE 1: 7 FT. 9.3 kW
ZONE 2: 4 FT. 31.7 kW
ZONE 3: 4 FT. 31.7 kW
ZONE 4: 4 FT. 15.8 kW
ZONE 5: 4 FT. 15.8 kW
ZONE 6: 4 FT. 15.8 kW
MAXIMUM HEATING POWER RATING: 120 kW
PREHEATING SECTION: STAINLESS STEEL INTERIOR W/CIRCULATION
FAN, FUME VENT, AND ACCESS DOOR
INSULATION SYSTEM: CERAMIC FIBER LINING CONSTRUCTED OF
2300 DEG. F. FIBER
ATMOSPHERE: OPEN AIR CHAMBER DESIGN, AIRFLOW
CURTAIN AT EXIT END
THERMOCOUPLES: (8) TYPE "K" AND (1) TYPE "J"
TEMPERATURE CONTROLS: (6) WEST MODEL No. N8101-Z2310
HIGH LIMIT CONTROLS: (2) WEST MODEL No. N6701-Z2100
TEMPERATURE INDICATOR: (1) OMEGA MODEL No. 1150KF
BELT DRIVE: DAYTON 1/4 HP MOTOR, DAYTON SPEED
CONTROLLER, & SUMITOMO GEAR REDUCER
EXHAUST HOOD: (1) 4' x 4'
ELECTRIC SERVICE: 480 V, 160 AMPS, 3 PH, 60 CYC
DOCUMENTATION: INSTALLATION, OPERATION AND
MAINTENANCE MANUALS
THE FURNACE WAS FULLY REBUILT BY KEITH COMPANY IN 2000, AND WAS
REGULARLY USED FOR PILOT SCALE PRODUCTION THROUGH MID 2003. IN THE
SUMMER OF 2003, THE FURNACE WAS PARTIALLY DISASSEMBLED AND MOVED INTO
STORAGE TO MAKE SPACE FOR OTHER PRODUCTION EQUIPMENT. THE SECTIONS
OF THE FURNACE ARE AVAILABLE FOR INSPECTION. THE FURNACE WAS FULLY
FUNCTIONAL WHEN IT WAS REMOVED FROM PRODUCTION, AND IS GENERALLY IN
ABOVE-AVERAGE CONDITION. THE BELT IS IN GOOD CONDITION, WITH SOME
SURFACE OXIDATION, BUT THE THICKNESS IS UNDIMINISHED, AND IT TRACKS
STRAIGHT WITH NO REPORTED PROBLEMS. THE PREHEATING SECTION SHOWS SOME
OXIDATION CONSISTENT WITH THE REGULAR REMOVAL OF FREE MOISTURE, BUT
THIS IS COSMETIC AND NOT STRUCTURAL. THE FURNACE IS MODULAR IN
CONSTRUCTION FOR EASE OF TRANSPORT.
**PRICE QUOTED IS EX WORKS AS IS WHERE IS SUBJECT TO PRIOR SALE**
**ALL SPECIFICATIONS ARE SUBJECT TO VERIFICATION BY PURCHASER**
Return to Menu
(Use your BACK function to return to previous screen.)